Discover More About Hipot Testers, Dielectric Strength Tests And Their Similarities And Dissimilarities

By Carl Hughes


Dielectric Withstand or hipot testing is done by applying high voltage between wire being tested and ground, presumably locomotive chassis. If excess current leakage or if an arc occurs, test fails. Insulation Resistance testing provides numerical value indicating resistance insulation. Information on how hipot testers work can be read below.

High Pots could be AC, DC and conducted sporadically, or at final assembly line stage, etc. Stress assessment results, in general, illustrates Pass Fail basing on current leak. For several systems, this method may bear out risks. Testing medium volt wire might also pose dangers.

Dielectric strength illustrates max electric field pure substances could endure under optimal conditions without tearing or without showing breakdown of its insulating attributes. Theoretical dielectric withstand is a natural object attribute on raw material and autonomously designed material or electrodes to which electrical field is flowed. This innate dielectric withstand communicate data on what needs measuring using raw materials subjected upon optimal laboratory setting.

In breakdown, electric field effectively frees bounded electrons. When applied electrical field is high, free electrons coming from background current radiation may be accelerated with velocities that may liberate additional bounded electrons upon meeting neutral atomic particles, molecules within avalanche breakdown. Breakdowns occur quite suddenly, typically nanoseconds, causing an electrical conduction path formation and disruptive discharge through material. Towards solid materials, breakdowns severely degrades, even neutralizing, its capability to insulate.

Regarding difference between insulation and dielectric testing, none exists. There should be no difference between insulation versus dielectric testing. Dielectrical strength simply shows how well insulator material. Now regarding testing, frequency test voltage should be determined by what voltage type insulating substance will expect during its operational life. Which means you should not DC withstand testing component that will be used for AC 5060 Hz applications.

While those above are simply two separate as well as very unlike engineering methods, those two are casually used around interchangeably within electrical engineering industry. So one cannot simply depend on those terms accurately describing what is currently being tested along with laboratory performance. For instance, in Handy Guide Electrical Tests, wherein Dielectric Tests is their defined an insulation opposing attribute test HiPot test mix.

Whereas, typically, HiPot tester being used for Di electric Strength Withstand test would suit utilization for an Insulation Resistance test. Specific terminology used would really depend on company you are working, dealing with. If it really matters, you need to read given procedure description itself.

An Insulation Resistance tests would always show DC. Di electric Strength tests would usually AC but could be DC. If one see if one other could go through elimination as they investigate similar things, electrical experiments were done before. Conclusion was that they are both needed as they provide different data as their results.

An accentuation on the two tests interchangeability will provide insignificance as most insulated substance are analyzed by the two tests as it hasty to categorizing your substance item based on just a single frequency, electrical current transmission when generally it works for both given they have same amounts. Utilizing 48v DC framework, for most part utilizing materials with optional rating around 600v air conditioning should get job done. As item does not come up short hipot, everyones content paying no attention to insulated item utilized.