Useful And Essential Facts About Hipot Tester

By Diane Bailey


The phrase hipot test means high potential or high voltage test. Another name used to refer to this test is dielectric withstand test. This is an analysis of electrical components that is done with the intention of checking for suitability of electrical insulation. The analysis is meant to ensure that there is no current leakage from one point to another in electrical devices. It is the opposite of continuity test. This is worth knowing about Hipot tester.

The test is nondestructive and capable of determining the sufficiency of electrical insulation. The test uses high voltage. The high voltage is applied to all electrical appliances for a certain time duration to ensure the insulation is more than marginal. High quantities of voltage are applied to the insulation in the process.

The purpose of the process is to determine if there is crushed or nicked insulation in a component. It also helps in identifying conductive or corrosive contaminants, braided shielding, and stray wire strands around conductors. Tolerance errors in cables and terminal spacing problems can also be identified easily using hipot testing. The voltage that is used in this process is usually two times greater than operating voltage.

Hipot testing is usually conducted using hipot analyzers. A typical tester usually connects one side of the supply to safety ground. The second side of the supply gets connected to the conductor that need to be tested. In this arrangement, there are only two kinds of contact to which conductors can be connected, that is, the ground and voltage.

In the situation there exist two contacts for which connection is needed, then a person must connect one to the ground while the other one to the voltage. This type of connection is vital. It makes sure that contacts are isolated from other forms of contacts. A small current will flow from one conductor to the other when a massive voltage is applied when the insulation placed between the two conductors is not adequate.

The flow of that tiny current is normally acceptable. However, a breakdown of air or solid insulation is supposed not to happen in any case. It is understood that any product is normally subjected to normal everyday transient over voltages. That is why high voltage is normally applied in these tests. Therefore, the product should remain safe and operational in event such differences in voltages happen during the day.

There are several requirements that are normally checked while carrying out this evaluation. The various requirements need the voltage to get applied for a distinct amount of time. Under IEC 06950 standards, the analysis is meant to be carried out continuously for a period of one minute. Nevertheless, a typical rule is to use 110-220 percent of working voltage of the product plus a thousand volts for 1 to 2 seconds.

There are also specifications for the amount of current that need to be applied. Currently, there are several different kinds of testers in the market that one can buy. Different testers are meant for different classes of products. As such, it is important to know which tester to use for certain applications.